Scheduling in <=16.1 R10 may crash Connexion

Scheduling in <=16.1 R10 may crash Connexion

CNXN-5162: FTP Device crashes execution group due to Scheduling Configuration

An issue was discovered which causes Connexion to crash under the following conditions:

  1. Utilize a device which supports a polling period as well as scheduling (Reader devices).

  2. Use Days & Hours scheduling mode

  3. Enable all days and hours

  4. Use a polling period equal to or greater than one hour.

Please disable scheduling (as day & hour scheduling which includes all periods is functionally the same), or, create a schedule with some blocks excluded.

Versions after 16.1R10 will throw an invalid configuration exception if days & hours is selected with all blocks included.

 