Released On | April 7, 2021 |
Release Type | Beta |
Connexion | .NET 4.8 may need to be manually installed if your systems don't have internet access. Internal Connexion libraries now target .NET 4.8. If you are referencing any Connexion assemblies other than Connexion.Core, you will need to target .NET 4.8 in your projects. Please note that all non-core libraries are internal and subject to change. Breaking Change - Connexion Unit Test API The Connexion Unit Test API has been expanded/changed. If you are using this feature please contact Conevity for further details. |
Integrator | Breaking Change! - Certificate Rotation15.0 R6 introduced Certificate Rotation which forces the Integrator to create a self-signed certificate on a rotating basis. If an Integrator is unable to communicate with the Gateway because of a downgrade to 15.0 R5 then you will need to use the "Break Glass" feature to re-establish the communications link. |
Installer Descriptions |
Ticket | Type | Summary |
---|---|---|
R4 Change Log
CNXN-4100: No messages were found in the file. Make sure framing settings are correct. |
Issue: When a corrupted file (typically HL7) is encountered by the file writer, the file is not ingested and an error is posted to the device (no message is posted on the queue). This corrupted file is never picked up and remains in the directory indefinitely (and an error is logged on each directory read). Solution: When the file reader has [Message Framing] enabled and a file is encountered containing zero valid messages, the contents of the file are read into a message and placed on the error queue. An error is logged to the device, and then source file is then deleted. If the file is large (Configurable via the UI), then it is added as an attachment to the message. For example, the following file is not valid HL7 as it is missing the MSH segment. Prior to R4, this file would not be ingested and an error logged on each read of the source directory. PID|||100001||CIERS^HANH^CHANTAY|^^CIERS|19340901|F||U|6834 RIO ESTRADA WAY^^SLC^UT^60561^USA^^SALT LAKE||(408)-131-3279|(408)-389-4489||||872-39-1819|872-39-1819|||||||||| PV1||O|NEPH^^|||^^|2190^TESTA^GIULIANO^^^|308447^ABBO^PAUL^R^^||TRP||||||||||BLUE CROSS||||||||||||||||||||||||201101111454| IN1|1|BC-PPO^|BLUE CROSS OF ILLINOIS||||(408)-374-7817|941-53-6056||||||||KORTHAUER^MISHA^GIHANHA|||953 BENBROOK LANE^^BURBANK^CA^^USA^^LOS ANGELES In R4, this file is read into a message and placed onto the error queue. |
CNXN-4099: Add Column to Connected User displaying their Authorization Role(s) comma delimited |
Improvement: The ability to easily view which Authorization Role(s) a currently logged on user is mapped to. |