Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

If the device should output the message as an XML string, select the Output as string option.

Using a custom schema

tbdYou can create a custom HL7 schema to use with incoming HL7 message. The scheme can be based on several different versions of the standard HL7 schema.

Image Added

To create a custom HL7 schema:

  1. From the Device panel for the HL7 to XML device click Add Schema.
  2. Enter a schema name, select the version of the HL7 schema you want to use as a base, and enter a description for the new schema (optional).
  3. Click Add.
  4. A screen will appear listing all of the segments, fields, data types, and code tables associate with the base schema. You can use the toolbar buttons to modify the standard schema elements as follows:
    1. Add a new segment/field/data type and members/code table
    2. Removed a segment/field/data type and members/code table
    3. Edit a segment/field/data type and members/code table
    4. Clone (copy) a segment/field/data type and members/code table
  5. For some elements, you can use the arrow buttons to reorder the values (for fields and data type members). You can copy values from another source and paste them into the table.

Close the window to save the schema. It will now appear in the HL7 Schema drop-down field and can be used by the device.

Image Added

Editing a schema

...